© 2007 D 162 - 08/07 8 of 32
VIEW MENU
Mode Item Field Range Access Description
1
OFF, -4°F (-20.0°C)
to Setpoint Maximum
(variable)
USEr
InST
ADV
SET SETPOINT (ON / OFF) SECTION A
Display the desired temperature.
2
OFF, -4°F (-20.0°C)
to Hot Tub Maximum
(variable)
USEr
InST
ADV
SET HOT TUB SECTION B
Display the desired temperature.
3
OFF, -4°F (-20.0°C)
to DHW Maximum
(variable)
USEr
InST
ADV
SET DHW SECTION C
Display the desired temperature.
4
OFF, -4°F (-20.0°C)
to Setpoint Maximum
(variable)
USEr
InST
ADV
SET SETPOINT (PWM) SECTION D
Display the desired temperature.
5
OFF, -4°F (-20.0°C)
to Floor Maximum
(variable)
USEr
InST
ADV
SET FLOOR SECTION E
Display the desired temperature.
6
OFF, -4°F (-20.0°C)
to Pool Maximum
(variable)
USEr
InST
ADV
SET POOL SECTION F
Display the desired temperature.
1
2
3
4
5
6
-31 to 266°F
(-35.0 to 130.0°C)
SEC
LTD
USEr
InST
ADV
OUTDOOR SECTION R
Displays the measured outdoor temperature.
Note:
This item is only available when the setpoint
control is connected to a tN4 bus and the Outdoor
item in the ADJUST menu is set to On.
1
2
3
4
5
6
-31 to 266°F
(-35.0 to 130.0°C)
InST
ADV
SUPPLY TEMP OF tN4 BUS SECTION R
Actual water temperature of the tN4 bus for
heating.
Note: This item is only available when the
setpoint control is connected to a tN4 System
Control, DIP switch 2 is set to tN4 System
Control, and the Heat Source item in the ADJUST
menu is set to hydronic (HYDr).
VIEW Menu (2 of 2)
After the last item, the control returns to the first item in the menu.